Flat Jack Method for Measuring Design Parameters for Hydraulic Structures of the Koyna Hydro Electric Project in India

Keshav Ral Dhawan

Cover Image

Abstract


The paper presents two different projects: The first involves a case with limited rock cover on a side of an excavated surge shaft located near a steep slope. The second involves the assessment of design parameters of an existing masonry dam for use as input in dynamic analysis. The induced stresses in the surge shaft of Koyna Hydro Electric Project (K.H.E.P.) stage-IV were measured with flat jack. These tests were first performed in a 4 m diameter pilot shaft and after the shaft was excavated to its full diameter of 22.70 m. The stresses increased from 3.96 MPa to 5.09 MPa, when the 4m-diameter surge shaft was expanded to its full diameter of 22.70 m, in the case where significant rock mass cover existed at EL 651.00 m. However stress reduction or no variation in the induced stress was measured in the portion of insufficient rock cover. In the second case, to determine the design parameters of Kolkewadi masonry dam of K.H.E.P stage-III, flat jack tests were conducted at the upstream side of Kolkewadi masonry dam in masonry of 1:4 and 1:3 and at downstream sloping side in masonry of 1:5. It is impractical and difficult to obtain mechanical properties of masonry in laboratory from the extracted core samples, due to intrinsic nonhomogeneity of the material. The brick/stone and mortar layers caused anisotropic behavior of masonry. Average deformation modulus for 1:3 masonry was 32.8 GPa. Similarly, the average deformation modulus for the 1:4 and 1:5 masonry was 19.0 and 13.7 GPa respectively and were adopted for the dynamic analysis. Induced stresses in the masonry dam were found to be nearly equal to the overburden.

Keywords


Flat jack, masonry dam, surge shaft, deformation modulus, induced stresses

Citation


Dhawan, K. R. (2012). Flat Jack Method for Measuring Design Parameters for Hydraulic Structures of the Koyna Hydro Electric Project in India, Vol. 2, Issue 3, p.182-195. doi: 10.4417/IJGCH-02-03-01




DOI: http://dx.doi.org/10.4417/IJGCH-02-03-01

Copyright © 2004-2018 Elxis s.a. All rights reserved. Powered by Argo-E LLC.